Ultrasonic double-sheet detectors monitor the intensity of an ultrasonic sound wave that makes it through the sensed material. The thicker the material, the lower the ultrasonic level received. The receiver then triggers one of three outputs for no sheet (high level), single sheet (calibrated level), or double sheet (low level).