Key parameters for the PLED are VBR, IS, IH, IT, and
VT, as shown in the V-I curve. VBR is the region from
the off-state voltage to breakdown voltage rating
of the device. In the off-state, VBR is the continuous
peak combination of ac and dc voltage that may be
applied to the device with less than 5 μA conducted
through it. IS is the value of current that makes
the device switch from the off to on-state when a
minimum VBR is applied. Holding current (IH) is the
minimum current needed to maintain the device in
the on state. On-state voltage (VT) is the maximum
voltage across the device during full conduction. IT
is the maximum rated current the device can carry
during the on-state for 2 sec.