The negative-stiffness vibration-isolation system uses three subsystems to isolate the payload from vibrations. The support spring, combined with the vertical negative-stiffness flexures, clamp, compression spring, and vertical-load and stiffness-adjustment screws, isolates the system from vertical vibrations. The beam-columns perform horizontal isolation. And the tilt flexure and damper isolate tilt vibrations from the payload.