Rephasing cylinders offer an innovative and costsaving solution for synchronized linear-actuator applications.

Printer-friendly version

The system includes two or more cylinders plumbed in series, with bore and rod diameters sized such that all rods extend or retract equally when flow routes to the first, or last, cylinder in the series. This hydraulic synchronization eliminates the need for a separate flow divider or mechanical torque tube. There's also no need for external circuitry, devices, or plumbing for synchronization.

Rephasing cylinders combine the functions of flow dividing/combining components with that of actuators, saving space and weight. In addition, accuracy reportedly equals or exceeds that of more-costly methods. Other advantages include lower parasitic power losses, pressure intensification, and the ability to transfer power between actuators. Both tie-rod and welded cylinders can be modified to take advantage of rephasing technology.

Energy Mfg. Co., 204 Plastic Lane, Monticello, IA 52310, (319) 465-3537, energymfg.com

Comments

rephasing cyl concepts

could someone knowledable please comment to following; why must the slave cyl in a rephasing system always be 1/4inch smaller,bore dia. Every piece of machinery in my fleet is this way. I would like to standardize my replacement parts supply and i need to understand the dynamics of the master/slave relationship. Any help would be greatly appreciated.

hydraulic cylinders

Does the rephasing setup exist for differential cylinders - I suppose not but I thought I'd ask at it would simplify considerably my design which requires two synchronised cylinders able to resist both push and pull loading.

Rephasing Hydraulic Cylinders

Please could you send me a technical documentation on the above subject with explanations about its principle and operating.
I cannot read the PDF file available on internet.

Best Regards,
Robert Pavillet